monitoring: temp dashboard shows max temp per host with 70°C warning line
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
This commit is contained in:
parent
7ad8fd479f
commit
6ee12c3270
1 changed files with 6 additions and 6 deletions
|
|
@ -52,10 +52,10 @@ data:
|
|||
"defaults": {
|
||||
"color": {"mode": "palette-classic"},
|
||||
"unit": "celsius",
|
||||
"custom": {"drawStyle": "line", "lineWidth": 1, "fillOpacity": 10, "showPoints": "never"},
|
||||
"custom": {"drawStyle": "line", "lineWidth": 2, "fillOpacity": 10, "showPoints": "never", "thresholdsStyle": {"mode": "line"}},
|
||||
"thresholds": {"mode": "absolute", "steps": [
|
||||
{"color": "green", "value": null},
|
||||
{"color": "red", "value": 85}
|
||||
{"color": "red", "value": 70}
|
||||
]}
|
||||
},
|
||||
"overrides": []
|
||||
|
|
@ -66,12 +66,12 @@ data:
|
|||
"legend": {"displayMode": "table", "placement": "bottom", "calcs": ["last", "max"]},
|
||||
"tooltip": {"mode": "multi"}
|
||||
},
|
||||
"title": "All temperature sensors",
|
||||
"title": "Highest temperature per host (warning line @ 70°C)",
|
||||
"type": "timeseries",
|
||||
"targets": [
|
||||
{"datasource": {"type": "prometheus", "uid": "${datasource}"},
|
||||
"expr": "node_hwmon_temp_celsius",
|
||||
"legendFormat": "{{instance}} / {{chip}} / {{sensor}}", "refId": "A"}
|
||||
"expr": "max by (instance) (node_hwmon_temp_celsius)",
|
||||
"legendFormat": "{{instance}}", "refId": "A"}
|
||||
]
|
||||
}
|
||||
],
|
||||
|
|
@ -87,5 +87,5 @@ data:
|
|||
"timezone": "Europe/Oslo",
|
||||
"title": "Hardware Temperatures",
|
||||
"uid": "hw-temps",
|
||||
"version": 1
|
||||
"version": 2
|
||||
}
|
||||
|
|
|
|||